AMI300
Multi-parameters portable device : Pressure, air velocity, airflow, hygrometry, temperature, air quality, tachometry.
Memory : up to 12 000 measurement points
Dataloger software for data recording and processing (option).
Supplied with calibration certificate and alu transport case.
Anemometer
- Ø 70 mm vane : 0,3 to 35 m/s
- Ø 100 mm vane : 0,3 to 35 m/s
- Ø 14 mm vane : 0,8 to 25 m/s
- Hotwire : 0,15 to 30 m/s
Thermometer
- Pt100 : -50 to 250°C
- Thermocouple K: -200 to +1300°c
- Thermocuple J : -100 to +750°C
- Thermocouple T : -200 to +400°C
Manometer
- 0 to ±500 Pa
- 0 à to ±2500 Pa
- 0 to ±10000 Pa
- 0 to ±500 mBar
- 0 to ±2000 mBar
- Pitot tube : 2 to 100 m/s
Hygrometer
- 3 to 98%HR
Air Quality (CO/CO2)
- 0 to 5000 ppm
Tachymeter
- 60 to 60 000 tr/min (optic)
- 30 to 20 000 tr/min (contact)
-
Relative humidity : from 3 to 98%RHHygrometry : capacitive sensorTemperature : Pt100 class 1/3 DIN Standard model : ABS handle and probe (from -20 to +80°C).High temperature model ...
-
Opticaltachometry probe : from 60 to 60 000 tr/minContactadaptor for optical tachometry probe : from 30 to 20 000 tr/min
-
Air velocity : from 0.15 to 30 m/sHygrometry : from 5 to 95%RHTemperature : from -20 to +80°C
-
CO / Temperature probe COCO2 / Temperature probeCO2 / Temperature / Hygrometry probe
-
Measurement module with2 pressureinputs and1 thermocoupleinput.5 models availablefrom -500 to +500 Pafrom -2500 to +2500 Pafrom -10000 to +10000 Pafrom -500 to +500 mbarfrom -2000 ...
-
KIMO offers a wide range of high-quality and accurate Pitot tubes, as per the AFNOR NFX 10-112 norm.Accuracy : More than 1 %, for a ± 10 ° alignment to the fluid flow. Pitot tube...
-
Applications : air supply systems in laboratories, air conditioning systems, air flow test rigs, fume extraction and exhaust systems, vacuum cleaning systems. KIMO DEBIMO flow me...
-
Thermocouple probe with lamella contact and spring for pipesApplication : Specific probe for the monitoring of pipes temperatureMeasuring range from -50°C à +250°C.K thermocouple p...
-
Measurement module with hygrometry, temperature and air pressure internal sensorRelative humidity : from 5 to 95 %RHTemperature : from -20 to +80°CAir pressure : from 800 to +1100 ...