SRIL-8 Logtag
SRIL-8 Logtag
Single-Use Low Temperature Recorder
The LogTag® Dry Ice “Probe-less” Temperature Recorder
operates, measures and stores up to 8000 temperature readings
in temperature environments ranging from -80°C to +40°C
(-112°F to +104°F)
Intended for use in transit monitoring of articles stored in
packaging incorporating dry ice cooling.
Available in single trip (SRIL-8) and multiple trip (TRIL-8)
versions. Using the LogTag® Interface Cradle and the freely
available companion software LogTag® Analyzer, these are
easily set-up for recording conditions including delayed start,
sampling interval, number of readings, continuous or fixed
number of readings and configuration of conditions to activate the 'ALERT' indicator. LogTag® Analyzer also provides
facilities for charting, zooming, listing data statistics and allows exporting the data to
other applications such as MS Excel once the data has been downloaded.
คุณลักษณะ
Model | SRIL-8 (Single use) |
Recorder Operating Measurement Range | -80°C ~ +40°C (-112°F ~ +104°F) |
Resolution | < than 0.1°C for -80°C ~ +0.0°C < than 0.2°C for -0.0°C ~ +20°C < than 0.5°C for +20°C ~ +40°C (see below) |
Accuracy | Better than ±1°C for -30°C ~ +20°C Better than ±1.2°C for -45°C ~ -30°C & +20°C ~ +40°C Better than ±1.7°C for -80°C ~ -45°C |
Sensor Reaction Time | Typically less than 5 minutes(T90) in moving air (1m/s) |
Capacity | 8000 readings (16K bytes memory) |
Sampling Frequency | Adjustable, 1~60 minutes or 1~18 hours |
Logging Start Options | Push button start or specific date & time. |
Recording Indication | Flashing 'OK' indicator / flashing 'ALERT' indicator. |
Download Time | Typically with full memory (8000 readings) in less than 5 secs depending on computer or readout device used. |
Environmental | IP65 (roughly equivalent to NEMA 4) |
Power Source | 3.6V low temperature chemistry Lithium battery |
Battery Life | Storage life of up to 12 months before ‘start’. Rated for a typical trip of 2 weeks duration at dry ice temperatures. |
Size | 86mm(H)x54.5mm(W)x8.6mm(T) |
Weight | 35g |
Case Material | Polycarbonate |
Other Features | • Logging start by push button or specific date/time start • Optional clearing of alert indication by push button (places inspection make at same time). • Download inspection mark recorded in LogTag memory every time LogTag is downloaded. • 'Prestart' fail-safe logging (records temperature data even if not started) • Low Battery indication in software. • Comprehensive Alert indicator configuration. • Calibration to achieve higher accuracy possible. |

Tested and complies with EC EMC directives (EN 50081-1:1992 & EN 61000-6-1:2001).
See LogTag® TRIL-8 & SRIL-8 CE mark EMC declaration of conformance
Tested and complies FCC Part 15 Subparts A and B. See LogTag® TRIL-8 & SRIL-8 FCC EMC declaration of conformance

Designed for FDA CFR21 Part 11 Digital signatures

The RoHS Directive stands for "the restriction of the use of certain hazardous substances in electrical and electronic equipment". This Directive bans the placing on the EU market of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants.